Strong soloist in warm tap water preparation
Plenty of warm water
The Consul+ is our combination of a direct fired complete warm water boiler with an insulated storage tank. As this combination is supplied completely pre-assembled, the installation is easy.
Direct fired boiler
The device that is installed on the tank is a direct fired boiler. The cold water is injected via the tank and subsequently heated by the boiler to the desired temperature. An important advantage of the direct fired system is the high efficiency (up to 108%), without interference and loss of an anti-power device.
Complete stainless steel version
The Consul+ is water-side completely made from stainless steel, with the only exception of a high-quality bronze tap water pump. Due to the high-quality material the Consul+ is a durable product. Apart from durability, the complete stainless steel version also ensures that a sacrificial anode is not necessary in the tank.
Control equipment
Apart from the unique boiler-tank combination Eco Heating Systems also brings a revolutionary warm water thermostat. This solution, that is ideal for sports facilities, for example, offers the option to control your boiler in such a way that it will provide an ideal water temperature at set times.
Saving energy with the consul
In the utility ‘indirect system’ are used more and more, whereby the central heating installation is also used for the warm water. By getting away from this principle and by applying direct tap water heating with the use of a condensing high efficiency Consul+ boiler, there is a significant saving on energy. Firstly, in summer the complete central heating installation does not have to be heated for tap water and secondly there are no transfer losses with direct tap water heating due to the compulsory separation of warm water and heating.
Features Consul+
✓ Supplied completely assembled
✓ Large continuous tap capacity
✓ Very quick heating time of a full storage tank
✓ Recovery time less than 10 minutes
✓ Fully stainless steel exchanger, tank and pipe work
✓ Compact construction method
✓ No waiting time for starting the boiler
✓ The device always condensates (so efficiency higher than 100%) during the tapping of tap water up to 60°C
✓ Adjustable tap water temperature from 35 to 75°C
✓ Pump switch for frost protection
✓ Link with GBS and company report possible
✓ Suitable for natural gas (K gas) and propane
Popular specifications
Device type: | Consul+ 35/150 | Consul+ 35/230 | Consul+ 55/230 | |
---|---|---|---|---|
Dimensions (h x w x d) | mm | 1525x610x1000 | 1565x610x1000 | 1565x610x1000 |
Water volume | liter | 150 | 150 | 230 |
Weight empty | kg | 97 | 114 | 117 |
Load (bottom value) | 10,1 – 33,7 | 10,1 – 33,7 | 14,0 – 51,0 | |
Capacity 80/60°C | 9,6 – 32,1 | 9,6 – 32,1 | 13,4 – 50,5 | |
Available flue-gas/air duct resistance* | 100 | 100 | 120 | |
*Maximum allowed joint flue-gas and air duct resistance measured when the device is burning at full load. |
General
Device type: | Consul+ 35 | Consul+ 55 | |
---|---|---|---|
Dimensions (h x w x d) | mm | 516 x 405 x 310 | |
Water volume | liter | 2,3 | 3,4 |
Weight empty | kg | 22 | 26 |
Cold and warm water connection | inch | R 1½ʺ | R 1½ʺ |
Connection size gas | inch | R ¾ʺ | R ¾ʺ |
Flue-gas/air concentric | mm | 80/125 | 80/125 |
Flue-gas/air parallel | mm | 80/80 | 80/80 |
Device type: | Consul+ 35/150 | Consul+ 35/230 | Consul+ 55/230 | |
---|---|---|---|---|
Dimensions (h x w x d) | mm | 1525x610x1000 | 1565x610x1000 | 1565x610x1000 |
Water volume | liter | 150 | 150 | 230 |
Weight empty | kg | 97 | 114 | 117 |
Capacity
Device type: | Consul+ 35 | Consul+ 55 | |
---|---|---|---|
Load (bottom value) | kW | 10,1 – 33,7 | 14,0 – 51,0 |
Load (bw) (G20 G25.3 G31) | kW | 11,2 – 37,4 | 15,6 – 58,8 |
Capacity 80/60°C | kW | 9,6 – 32,1 | 13,4 – 50,5 |
Capacity 50/30°C | kW | 10,4 – 34,7 | 14,2 – 53,7 |
Capacity 37/30°C | kW | 10,8 – 36,3 | 15,1 – 57,1 |
Gas consumption
Device type: | Consul+ 35 | Consul+ 55 | ||
---|---|---|---|---|
Natural gas G25.3 | m³st/u | 1,24 – 4,15 | 1,72 – 6,51 | |
Natural gas G20 | m³st/u | 1,07 – 3,57 | 1,48 – 5,60 | |
Propane G31* | m³st/u | 0,41 – 1,38 | 0,57 – 2,16 | |
Gas connection pressure nom. (min. – max.) |
G25.3 | mbar | 25 (20 – 30) | |
G20 | 20 ( 17 – 25) | |||
G31 | 30 (25 – 35) / 37 (25 – 45) | |||
*With the use of propane G31 the maximum ventilator speed must be reduced (parameter P4BD) |
Emission
Device type: | Consul+ 35 | Consul+ 55 | ||
---|---|---|---|---|
CO2 flue-gas min-max* | G25.3/G20 | % | 8,7 – 9,0 | 8,7 – 9,0 |
G31 | % | 9,3 – 10,3 | 9,3 – 10,3 | |
Noise capacity level (EN 15036-1:2006) |
dB(A) | 61 | 61 | |
NOx classification [EN15502-1] | 6 | |||
TTemp. flue-gas at combustion air temperature 20°C |
°C | ~ 85-95 | ||
Flue-gas mass flow [min-max] (Q flue-gas; condensing) | g/s | 17,48 | 27,44 | |
Available flue-gas/air duct resistance** | Pa | 100 | 120 | |
* CO2 of the device measured/set without installed boiler door ** Maximum allowed joint flue-gas and air duct resistance measured when the device is burning at full load. |
Installation
Toesteltype | Consul+ 35 | Consul+ 55 | |
---|---|---|---|
Maximum water temperature | °C | 75 | |
Water pressure boiler min-max | bar | 1,0 – 8,0 | |
class=”td-left”>Overflow pressure max | bar | 10 | |
Max. available boosting height of the pump at ΔT = 17 K | mWK | 2,8 | 2,7 |
Electric
Device type: | Consul+ 35 | Consul+ 55 | |
---|---|---|---|
Included electrical power measured without pump. |
W | 55 | 90 |
Electrical supply | V / Hz | 230 / 50 | |
IP classification | IPX4D |
Device type: | Consul+ 35/150 | Consul+ 35/230 | Consul+ 55/230 | |
---|---|---|---|---|
Included electrical power complete system |
W | 160 | 160 | 195 |
Other
CE product ID number | CE 0063 BR3537 |
Gas category | II2EK3P |
Device category | B23; C13, C33, C43, C53, C63, C83. |
Fire brigades Wijster, NL
Hot water: 1 Consul 55 with a 230 liter storage tank
Villa in Doorn, NL
Hot water: 1 Consul 35 with a 230 liter storage tank
Sanitary unit for camping facility
Hot water: 1 Consul 55 with a 230 liter storage tank combined with solar panels