Ambassador+ product info

Versatile and flexible heating

The Ambassador+ is a compact wall-hung central heating boiler with a practical design and surprising versatile possibilities. The stainless-steel heat exchanger, with a 10-year warranty, has a very long lifespan. The Ambassador+ units can simply be cascaded thanks to the integrated cascade controller. This way the units will operate as one central heating system.

Features

✓ Suitable for Building Management Systems (BMS)
✓ Programmable clock
✓ Integrated real time clock
✓ Freely programmable priority for central heating or warm water
✓ Remote boiler status signal possible
✓ High efficient two-step boiler flow control
✓ Quick and easy to installation
✓ Easy maintenance
✓ Suitable for natural gas, butane and propane

 

Popular specifications

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Dimensions (h x b x d) mm 842 x 476 x 486 898 x 476 x 677
Weight empty kg 46 73 78 83 92 101
Parallel flue-gas/air connection mm 80-80 80-80 100-100 100-100 130-130 130-130
Nominal input (Net) kW 12,5 – 55,6 14,6 – 74,3 17,2 – 92,2 26,0 – 111 34,0 – 138 45,0 – 166
Nominal input 80/60°C kW 12,0 – 53,5 14,0 – 71,2 16,5 – 88,4 24,7 – 106 32,6 – 132 43,3 – 160
Efficiency 40/30°C DIN 4702-8 % up to 110.6 % within the Ambassador+ range
Max. pressure for flue/air system* Pa 200
*Maximum allowed combined resistance of flue gas and air supply piping at high output

 

 

General

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Dimensions (h x b x d) mm 842 x 476 x 486 898 x 476 x 677
Water content liter 3,9 5,0 6,5 8,3 10,4 12,9
Weight empty kg 46 73 78 83 92 101
Flow/return connection boiler inch R 1″ R 1″ R 1″ R 1″ R 1¼” R 1¼”
Flow/return connection after T-piece inch Rp 1¼” Rp1¼” Rp 1¼” Rp 1¼” Rp 1½” Rp 1½”
Gas connection size inch R ¾” R ¾” R ¾” R ¾” R 1″ R 1″
Concentric flue-gas/air connection mm 80/125 80/125 100/150 100/150 100/150 100/150
Parallel flue-gas/air connection mm 80-80 80-80 100-100 100-100 130-130 130-130

 

Capacity

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
kW 12,5 – 55,6 14,6 – 74,3 17,2 – 92,2 26,0 – 111 34,0 – 138 45,0 – 166
Nominal input (gross) (G20, G25) kW 13,9 – 61,8 16,2 – 82,5 19,1 – 102 28,9 – 123 37,8 – 153 50,0 – 184
Nominal input (gross) (G31) kW 13,6 – 60,4 15,9 – 80,8 18,7 – 100 28,3 – 121 37,0 – 150 48,9 – 180
Nominal input (gross) (G30/G31) kW 13,5 – 60,3 15,8 – 80,2 18,6 – 99,7 34,7 – 120 36,8 – 150 48,8 – 180
Nominal output 80/60°C kW 12,0 – 53,5 14,0 – 71,2 16,5 – 88,4 24,7 – 106 32,6 – 132 43,3 – 160
Nominal output 50/30°C kW 12,9 – 57,4 15,2 – 77,5 18,0 – 96,2 27,2 – 116 35,5 – 144 47,3 – 175
Nominal output 37/30°C kW 13,5 – 59,8 15,7 – 80,1 18,6 – 99,5 28,1 – 120 36,7 – 149 48,5 – 179
Efficiency 40/30°C DIN 4702-8 % up to 110.6 % within the Ambassador+ range

 

Gas consumption

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Natural gas G25.3 m³st/u 1,50 – 6,69 1,76 – 8,94 2,07 – 11,1 3,13 – 13,4 4,09 – 16,6 5,41 – 20,0
Natural gas G20 m³st/u 1,32 – 5,88 1,54 – 7,86 1,82 – 9,76 2,75 – 11,8 3,60 – 14,6 4,76 – 17,6
Propane G31* m³st/u 0,51 – 2,27 0,60 – 3,04 0,70 – 3,77 1,06 – 4,54 1,39 – 5,65 1,84 – 6,79
Butane/Propane (B/P) G30/G31* m³st/u 0,39 – 1,72 0,45 – 2,29 0,53 – 2,85 0,99 – 3,44 1,05 – 4,28 1,40 – 5,15
Gas supply pressure
nom. (min. – max.)
G25.3 mbar 25 (20 – 30)
G20 mbar 20 (17 – 25)
G31* mbar 30 (25 – 35) / 37 (25 – 45)
G30* mbar 50 (43 – 57)
*Using propane or butane/propane mixtures (B/P), maximum fan speed needs to be reduced (parameter P4BD)

 

Emission

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
CO2 flue gas* G25.3/G20 % 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0
G31 % 9,3 – 10,3 9,3 – 10,3 9,3 – 10,3 9,3 – 10,3 9,3 – 10,4 9,3 – 10,5
G30 (B/P) % 9,3 – 10,4 9,3 – 10,4 9,3 – 10,4 9,3 – 10,4 9,3 – 10,5 9,3 – 10,6
Sound power level, indoors
(EN 15036-1:2006)
65 67 65 62 66 69
NOx class [EN15502-1] 6
Flue-gas temperature at
combustion air temperature = 20°C
°C ~ 85-95
Mass flow flue-gas g/s 28,9 38,6 47,9 57,7 71,7 86,2
Available pressure for the flue system** Pa 200
*CO2 of the unit measured/set without the boiler front panel in place
**Maximum allowed combined resistance of flue gas and air supply piping at high output

 

Installation

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Available pressure for
the installation at
ΔT = 20 K mWK 5,9 3,1 2,3 1,5 6,0 4,8
ΔT = 25 K mWK 7,0 5,5 5,0 4,4 9,0 7,9
Pressure boiler min-max bar 1,0 – 4,0*
Max. flow temperature °C 90
*When the integrated water pressure sensor is replaced by a water pressure switch, water pressure may go up to 6,0 bar

 

Electric

Boiler type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Maximum power consumption W 240 265 270 280 505 520
Power supply V/Hz 230/50
Protection class IPX4D

 

Other

Product Identification Number CE 0063 BP3254
Gas Appliance Type II2L3B/P
Classification B23, B23P; C13X, C23X, C33X, C43X, C53X, C63X, C83X

Apartments Groningen, NL

Hot water: 2 pieces of CD 100 combined with 2 pieces of 300 liter storage tanks
Central heating: 3 pieces of Ambassador+ 180 and 1 piece of Ambassador+ 150

Posted in projects ambassador+, living | Comments Off on Apartments Groningen, NL

Health Sciences in Groningen, NL

Central Heating: 4 pieces of SB+ 120
Hot water: 2 pieces of CD+ 100 combined with a 750 liter storage tank

Posted in projects ambassador+ | Comments Off on Health Sciences in Groningen, NL

Police Academy in Zwolle, NL

Central heating: 2 pieces of Ambassador+ 80
Hot water: 1 CD 120 combined with a 300 liter storage tank

Posted in government, projects ambassador+ | Comments Off on Police Academy in Zwolle, NL

Marianum college in Groenlo, NL

Central heating: 2 pieces of Ambassador+ 150 with 2 pieces Ambassador+ 180
Hot water:: Consul 55-230

Posted in education, projects ambassador+ | Comments Off on Marianum college in Groenlo, NL

Biesdel care facility in Velp, NL

Hot water: 2 pieces of CD+ 80 combined with a 450 liter storage tank
Central heating: 3 pieces of Ambassador+ 180 cascaded

Posted in projects ambassador+, care | Comments Off on Biesdel care facility in Velp, NL

Huuskes in Enschede, NL

Central heating: 8 pieces of Ambassador+ 180 cascaded

Posted in companies, projects ambassador+ | Comments Off on Huuskes in Enschede, NL

Ariënhuis care facility in Glanerbrug, NL

Central Heating: 3 pieces of Ambassador+ 100
Hot water: 1 CD 120

Posted in projects ambassador+, care | Comments Off on Ariënhuis care facility in Glanerbrug, NL

Music Centre in Enschede, NL

Central heating: 7 pieces of Ambassador+ 180

Posted in culture, projects ambassador+ | Comments Off on Music Centre in Enschede, NL

Apartments in Enschede, NL

Posted in projects ambassador+, living | Comments Off on Apartments in Enschede, NL

De Teuge in Zutphen, NL

Central heating: Cascade of 6 Ambassador+ 180 boilers

Posted in projects ambassador+ | Comments Off on De Teuge in Zutphen, NL

Cascade productinfo

Modular customized system for any boiler room

The incorporated cascade regulator makes the Ambassador+ the ideal boiler for cascade systems up to twelve boilers. Simple looping and straight-forward connections make the installation easy. With the supplied cascade rack, a capacity of more than two megawatts can be installed in the most inaccessible areas. The system is equipped with adjustable legs and does not have to be anchored to the wall.

Features cascade
✓ Complete cascade set including assembly manual
✓ Water-side supply and return pipe
✓ Open distributor
✓ Gas-side distributor
✓ Open distributor sensor
✓ Connection set for the individual boilers
✓ Flue-gas drainage material (stainless steel roof outlet, adhesive plate, 1.5 metres extension pipe and 2 bends of 45º)

Popular specifications

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Dimensions (h x w x d) mm 842 x 476 x 486 898 x 476 x 677
Weight empty kg 46 73 78 83 92 101
Parallel flue-gas/air connection mm 80-80 80-80 100-100 100-100 130-130 130-130
Load (bottom value) kW 12,5 – 55,6 14,6 – 74,3 17,2 – 92,2 26,0 – 111 34,0 – 138 45,0 – 166
Capacity 80/60°C kW 12,0 – 53,5 14,0 – 71,2 16,5 – 88,4 24,7 – 106 32,6 – 132 43,3 – 160
Efficiency 40/30°C DIN 4702-8 % up to 110.6 % within the Ambassador+ range
Available flue-gas/air duct resistance* Pa 200
*Maximum allowed external joint resistance flue-gas and air duct on full load

 

General

Device type: A+
60
A+
80
A+
100
A+
120
A+
150
A+ 1
80
Dn
Dimensions (h x w x d)
mm 842 x 476 x 486 898 x 476 x 677
Water volume liter 3,9 5,0 6,5 8,3 10,4 12,9
Weight empty kg 46 73 78 83 92 101
Flow/return connection boiler inch R 1″ R 1″ R 1″ R 1″ R 1¼” R 1¼”
Flow/return connection after T-piece inch Rp 1¼” Rp1¼” Rp 1¼” Rp 1¼” Rp 1½” Rp 1½”
Connection size gas inch R ¾” R ¾” R ¾” R ¾” R 1″ R 1″
Concentrated flue-gas/air connection mm 80/
125
80/
125
100/
150
100/
150
100/
150
100/
150
Parallel flue-gas/air connection mm 80-80 80-80 100-100 100-100 130-130 130-130

 

Capacity

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Load (bottom value) kW 12,5 – 55,6 14,6 – 74,3 17,2 – 92,2 26,0 – 111 34,0 – 138 45,0 – 166
Load (bw) (G20, G25) kW 13,9 – 61,8 16,2 – 82,5 19,1 – 102 28,9 – 123 37,8 – 153 50,0 – 184
Load (bw) (G31) kW 13,6 – 60,4 15,9 – 80,8 18,7 – 100 28,3 – 121 37,0 – 150 48,9 – 180
Load (bw) (G30) kW 13,5 – 60,3 15,8 – 80,2 18,6 – 99,7 34,7 – 120 36,8 – 150 48,8 – 180
Capacity 80/60°C kW 12,0 – 53,5 14,0 – 71,2 16,5 – 88,4 24,7 – 106 32,6 – 132 43,3 – 160
Capacity 50/30°C kW 12,9 – 57,4 15,2 – 77,5 18,0 – 96,2 27,2 – 116 35,5 – 144 47,3 – 175
Capacity 37/30°C kW 13,5 – 59,8 15,7 – 80,1 18,6 – 99,5 28,1 – 120 36,7 – 149 48,5 – 179
Efficiency 40/30°C DIN 4702-8 % up to 110,6 % within the Ambassador+ range

 

Gas consumption

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Natural gas G25 m³st/u 1,54 – 6,84 1,80 – 9,14 2,12 – 11,4 3,20 – 13,7 4,18 – 17,0 5,54 – 20,4
Natural gas G20 m³st/u 1,32 – 5,88 1,54 – 7,86 1,82 – 9,76 2,75 – 11,8 3,60 – 14,6 4,76 – 17,6
Propane G31* m³st/u 0,51 – 2,27 0,60 – 3,04 0,70 – 3,77 1,06 – 4,54 1,39 – 5,65 1,84 – 6,79
Butane (B/P) G30* m³st/u 0,39 – 1,72 0,45 – 2,29 0,53 – 2,85 0,99 – 3,44 1,05 – 4,28 1,40 – 5,15
Gas connection pressure
nom. (min. – max.)
G25 mbar 25 (20 – 30)
G20 mbar 20 (17 – 25)
G31* mbar 30 (25 – 35) / 37 (25-45)
G30* mbar 50 (43 – 57)
*With the use of propane or butane/propane mixture (B/P) the ventilator speed must be reduced (parameter P4BD)

 

Emission

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
CO2 flue-gas* G25/G20 % 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0 8,7 – 9,0
G31 % 9,3 – 10,3 9,3 – 10,3 9,3 – 10,3 9,3 – 10,3 9,3 – 10,4 9,3 – 10,5
G30 (B/P) % 9,3 – 10,4 9,3 – 10,4 9,3 – 10,4 9,3 – 10,4 9,3 – 10,5 9,3 – 10,6
Noise capacity level
(EN 15036-1:2006)
65 67 65 62 66 69
NOx-classification [EN483 / EN15420] 6
Flue-gas temperature at
combustion air temperature = 20°C
°C ~ 85-95
Max. flue-gas volume g/s 28,9 38,6 47,9 57,7 71,7 86,2
Available flue-gas/air duct resistance** Pa 200
*CO2 of the device measured/set without installed front panel
** Maximum allowed external joint resistance flue-gas and air duct on full load

 

Installation

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Available resistance of
the installation at
ΔT = 20 K mWK 3,8 1,3 1,5 1,0 0,7 0,1
ΔT = 25 K mWK 5,1 3,7 3,7 3,0 3,2 2,5
Water pressure boiler min-max bar 1,0 – 4,0 5
Max. flow temperature °C 90
*With a water pressure switch instead of the standard incorporated water pressure sensor the boiler pressure can be 6.0 bar

 

Electric

Device type: A+ 60 A+ 80 A+ 100 A+ 120 A+ 150 A+ 180
Max. included electrical power W 240 265 270 280 505 520
Supply V/Hz 230/50
IP classification IPX4D

 

Other

CE product ID number CE 0063 BP3254
Gas category II2L3B/P
Device category B23, B23P; C13X, C23X, C33X, C43X, C53X, C63X, C83X

Apartments Groningen, NL

Hot water: 2 pieces of CD 100 combined with 2 pieces of 300 liter storage tanks
Central heating: 3 pieces of Ambassador+ 180 and 1 piece of Ambassador+ 150

Posted in projects ambassador+, living | Comments Off on Apartments Groningen, NL

Health Sciences in Groningen, NL

Central Heating: 4 pieces of SB+ 120
Hot water: 2 pieces of CD+ 100 combined with a 750 liter storage tank

Posted in projects ambassador+ | Comments Off on Health Sciences in Groningen, NL

Police Academy in Zwolle, NL

Central heating: 2 pieces of Ambassador+ 80
Hot water: 1 CD 120 combined with a 300 liter storage tank

Posted in government, projects ambassador+ | Comments Off on Police Academy in Zwolle, NL

Marianum college in Groenlo, NL

Central heating: 2 pieces of Ambassador+ 150 with 2 pieces Ambassador+ 180
Hot water:: Consul 55-230

Posted in education, projects ambassador+ | Comments Off on Marianum college in Groenlo, NL

Biesdel care facility in Velp, NL

Hot water: 2 pieces of CD+ 80 combined with a 450 liter storage tank
Central heating: 3 pieces of Ambassador+ 180 cascaded

Posted in projects ambassador+, care | Comments Off on Biesdel care facility in Velp, NL

Huuskes in Enschede, NL

Central heating: 8 pieces of Ambassador+ 180 cascaded

Posted in companies, projects ambassador+ | Comments Off on Huuskes in Enschede, NL

Ariënhuis care facility in Glanerbrug, NL

Central Heating: 3 pieces of Ambassador+ 100
Hot water: 1 CD 120

Posted in projects ambassador+, care | Comments Off on Ariënhuis care facility in Glanerbrug, NL

Music Centre in Enschede, NL

Central heating: 7 pieces of Ambassador+ 180

Posted in culture, projects ambassador+ | Comments Off on Music Centre in Enschede, NL

Apartments in Enschede, NL

Posted in projects ambassador+, living | Comments Off on Apartments in Enschede, NL

De Teuge in Zutphen, NL

Central heating: Cascade of 6 Ambassador+ 180 boilers

Posted in projects ambassador+ | Comments Off on De Teuge in Zutphen, NL